-Euro-raster Cassette Unit-
2-PIPE |
|
| Cod produs |
Capacitate aprox [kW] |
| FWF02 |
1.70
2.60 |
| FWF03 |
2.80
3.40 |
| FWF04 |
3.30
4.10 |
| FWF05 |
4.00
5.30 |
| |
| 4-PIPE - 4 capacity sizes: |
| FWF02 |
1.70
3.10 |
| FWF03 |
2.30
3.30 |
| FWF04 |
2.80
3.90 |
| FWF05 |
3.50
4.80 |
|
-Accessories-
| BYFQ60B |
Decoration Panel 4-way blow |
| KDBH44BA60 |
Sealing member of air discharge outlet |
| KDBQ44B60 |
Panel spacer |
| KAFQ441BA60 |
Long-life filter |
| KDDQ44XA60 |
Fresh air intake kit |
| BRC7E530 |
(13) Remote control Infrared H/P |
| BRC7E531 |
(13) Remote control Infrared C/O |
| BRC315D |
(1) Remote Control Wired |
| DCS302C51 |
(2) Central remote control |
| KJB311A |
Electrical box with earth terminal (3 blocks) |
| DCS301B51 |
(6) Unified on/off control |
| KJB212A |
Electrical box with earth terminal (2 blocks) |
| DST301B51 |
(6)(9) Shedule timer |
| KRP2A52 |
(5)(9) Wiring adapter for electrical appendices 1 |
| KRP4A53 |
(5)(9) Wiring adapter for electrical appendices 2 |
| KRP1BA101 |
(10) Installation box for adapter PCB |
| KRCS01-1 |
Remote Sensor |
| DCS601C51 |
(3)(8) Intelligent touch controller |
| KJB411A |
Electrical installation box |
| EKFCMBCB |
(5)(9) Optional PCB for MOD-bus connection |
| EKMV2C09B |
(5)(7)(11) 2-way valve - On/Off |
| EKMV3C09B |
(5)(7)(11) 3-way valve - On/Off |
| EKRP1C11 |
Valve control PCB |
| EKRORO |
(12) Remote “On/Off” and “forced off” kit |
|
| Notes: |
|
|
|
| 1. Optional, electrical installation box with earth terminal KJB212A is required, if controller wires need to be installed in the wall. |
| 2. Requires electrical installation box with earth terminal KJB311A. |
|
|
| 3. Requires electrical installation box KJB411A. |
|
|
| 5. Requires installation box KRP1BA101. |
|
|
| 6. Requires electrical installation box with earth terminal KJB212A, if built in the wall. |
| 7. Requires valve control PCB EKRP1C11. |
|
|
| 8. I-touch: |
|
|
|
| • Not allowed to use the i-touch for an installation with both fan coils and VRV units. |
| • Can not be used in combination with fan coil units, that use MOD bus communication. |
| • No Airnet or telephone connection possible. |
|
|
| 9. Only 1 of these 4 options can be installed on 1 indoor unit. |
|
|
| 10. Max. 2 KRP1BA101 boxes can be mounted on the unit. Max. 1 PCB can be mounted in 1 KRP1BA101 box. |
| 11. 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11. |
| 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11. |
| 12. This option is needed to create T1 T2 wire. |
|
|
| 13. It is possible to change the operation mode, but this will not have an impact on the water temperature. |
| (No feed back to water source) |
|
|
| It is not possible to select the “auto air flow” setting. |
|
|
| Dry operation can be selected with this remote control, but this function is not available on the FWF model. |
| 14. All options are supplied as kit. |
|
|
|